Premier Fire Testing Laboratory

For testing and approval of materials covered by fire regulations

Talk to an Expert
Prospec fire testing lab
Global Compliance
Cutting-edge fire testing capabilities to help you meet global safety standards
Rapid Testing
Faster turnaround times to accelerate your time-to-market
Expert Analysis
Highly experienced team of fire safety experts to provide comprehensive analysis and reports
Fire Testing
Our popular fire test services
Fire Testing
View All
Our popular fire test services
Smoke Density & Toxicity
(ISO 5659-2)
Types of Sample:
Cables, cable containment, relay, mcb, contractors, switch, PCB, Flexible metal, rubber, hose, Fibre reinforced plastic, Laminate, DGFRP, LP sheet, Compreg, Plywood, Upholstery, PU foam, Leather, silicon foam, coated fabric , PVC flooring, Honeycomb sheet, Painted sheet, Acrylic sheet, GFRE, NAFTC sheet, Compressed Laminate phenolic resin sheet, Phenolic GRP
Sample Conditioning Time
: 24 hrs or more & 168 hrs
Sample Size
: 75 X 75 mm
Sample Qty
: 12
Test Parameter
: Ds Max, CITg, Ds4,VOF4
Test Duration
: Approx 30 Min
Cone Calorimeter
(ISO 5660-1)
Types of Sample:
Cables, cable containment, Flexible metal, rubber, Fibre reinforced plastic, Laminate, DGFRP, LP sheet, Compreg, Plywood, Upholstery, PU foam, Leather, silicon foam, coated fabric , PVC flooring,Honeycomb sheet, Painted sheet, acrylic sheet, hose pipe,GFRE, NAFTC sheet, Compressed Laminate, phenolic resin sheet, Phenolic GRP
Sample Conditioning Time
: 24 hrs or more & 168 hrs
Sample Size
: 100 X 100 mm
Sample Qty
: 6
Test Parameter
: Maximum Average Rate of   Heat Emission (MARHE)
Test Duration
: Approx 32 Min
Lateral Spread of Flame
(ISO 5658-2)
Types of Sample:
DGFRP, GFRE, LP, NAFTC, Compressed Laminate, Compreg, Phenolic resin sheet, Painted sheet, Fibre reinforced plastic, Phenolic GRP,Fire retardant Plywood
Sample Conditioning Time
: 24 hrs or more
Sample Size
: 800 X 155 mm
Sample Qty
: 12
Test Parameter
: Critical flux at extinguishment,  CFE
Test Duration
: Approx 30 Min
Flooring Radiant Panel
(ISO 9239-1)
Types of Sample:
Floor carpet, PVC flooring, vinyl flooring, pvc free flooring, compreg
Sample Conditioning Time
: At least 72 hrs
Sample Size
: 1050 X 230 mm
Sample Qty
: 6
Test Parameter
: Wind opposed burning behaviour,   CFE
Test Duration
: Approx 30 Min
Industries we serve
Railways
Building
Marine
Automobile
Textile
Defence
Explore Fire Tests
About Us
Prospec is pioneering the establishment of a world-class fire test laboratory in India.
As the most advanced lab in the region, Prospec has undertaken extensive R&D to develop advanced testing procedures that ensure rapid testing and certification of your products and systems.
Team
Our leadership

Sushant and Prashant Gupta are pioneers in the fire testing industry with over 50 years of combined experience. Along with Mr. Kuldeep Dhingra in 1996, as the founding team of Spectro Analytical Labs, they played a crucial role in establishing the company  as one of the top five in India's TIC (Testing, Inspection & Certification) space. Sushant, with his extensive background in marketing, international project management, and public-private partnership projects, has been instrumental in gaining recognition from various industries and government bodies. Prashant, with his expertise in project management and laboratory setup for both private and government clients, has led the way in delivering top-notch services to notable clients such as Reliance, Hinduja National Power Corporation Ltd, Integral Coach Factory, DRDO, and RDSO. Together, they bring unparalleled knowledge of testing and compliance requirements across multiple industries, driving innovation and excellence in every project they undertake.

Mr. Sushant Gupta
Director - Marketing & Finance
Having started his career in early 1995, Mr. Sushant Gupta’s success is based almost exclusively on his commitment, dedication & unshakeable determination to work tirelessly towards his goals.
Mr. Prashant Gupta
Director - Operations
Since his early years, Mr. Prashant Gupta loved to build things. From his childhood passion for building blocks to gradually structuring the framework of numerous successful deals; his journey has been remarkable.
Get in touch
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
A1 sector 28,
Near sector 28 metro station,
Faridabad, Haryana, 121008.
Follow Us