Ignitability
Ignitablity Chamber

(EN,ISO 11925-2)
Types of Sample:
Laminate, Upholstery, PU foam. Leather, silicon foam,
 acrylic, water proofing membrane, acp pane, cladding,
Sample Conditioning Time
: 24 hrs or more & 168 hrs
Sample Size
: 250 X 90 & 250 X 180 mm
Sample Qty
:  1 & 1
Test Parameter
: Ignitability
Test standard
: EN ISO 11925-2, UIC-564 -2
Test Duration
: Approx 30 mins
Sample report
:
Flammabilty Chamber

(UL-94)
Types of Sample:
Plastic sheet, Polymer sheet, Fibre reinforced plastic,
Laminate
Sample Conditioning Time
: 23±2 °C & 50±5% RH, 48 hrs for 5 samples and Other 5 samples 70±1 °C, 168 hrs then 4 hrs in decicator
Sample Size
: 1050 x 230 mm
Sample Qty
: 10
Test Parameter
: V0 and HB class
Test standard
: UL-94; IS 6746:1994 Clause 4.4, ASTM D635, IS 11731 (Part 1& 2),
ASTM D4986-10, ISO 9772.
Test Duration
: Approx 60 mins
Sample report
:
Limmiting Oxygen Index
(EN,ISO 4589-2, IS 13501)
Types of Sample:
Cables, cable containment, Flexible metal, rubber,
Fibre reinforced plastic, Laminate, DGFRP, LP sheet,
Compreg, Plywood, Upholstery, PU foam, Leather,
silicon foam, coated fabric , PVC flooring, Honeycomb
sheet, Painted sheet, acrylic sheet, hose pipe, GFRE,
NAFTC sheet, Compressed Laminate, phenolic resin sheet
Upholstery, Coated fabric
Sample Conditioning Time
: 23±2 °C & 50±5 %RH for 88 hrs
Sample Size
: Different types
Sample Qty
:  15
Test Parameter
: Oxygen Index(%)
Test standard
: ISO 4589-2; ASTM D 2863; IS 13501;
IS 13660. ISO 4589-3.
Test Duration
: Approx 180 Sec
Sample report
:
UL 1581 wire flame test
Types of Sample:
,
Sample Conditioning Time
:
Sample Size
:
Sample Qty
:
Test Parameter
:
Test standard
:
Test Duration
:
Sample report
: